AMBIENTUM BIOETHICA BIOLOGIA CHEMIA DIGITALIA DRAMATICA EDUCATIO ARTIS GYMNAST. ENGINEERING EPHEMERIDES EUROPAEA GEOGRAPHIA GEOLOGIA HISTORIA HISTORIA ARTIUM INFORMATICA IURISPRUDENTIA MATHEMATICA MUSICA NEGOTIA OECONOMICA PHILOLOGIA PHILOSOPHIA PHYSICA POLITICA PSYCHOLOGIA-PAEDAGOGIA SOCIOLOGIA THEOLOGIA CATHOLICA THEOLOGIA CATHOLICA LATIN THEOLOGIA GR.-CATH. VARAD THEOLOGIA ORTHODOXA THEOLOGIA REF. TRANSYLVAN
|
|||||||
Rezumat articol ediţie STUDIA UNIVERSITATIS BABEŞ-BOLYAI În partea de jos este prezentat rezumatul articolului selectat. Pentru revenire la cuprinsul ediţiei din care face parte acest articol, se accesează linkul din titlu. Pentru vizualizarea tuturor articolelor din arhivă la care este autor/coautor unul din autorii de mai jos, se accesează linkul din numele autorului. |
|||||||
STUDIA CHEMIA - Ediţia nr.3 din 2017 | |||||||
Articol: |
INVESTIGATION ON IMAGE PROCESSING PARAMETERS FOR PLATE EVALUATION IN TLC ANALYSIS OF MYCOTOXINS. Autori: DORINA CASONI, MIHAELA BADEA, ILDIKO BROS, SIMONA CODRUTA AURORA COBZAC. |
||||||
Rezumat: DOI: https://doi.org/10.24193/subbchem.2017.3.07 Published Online: 2017-09-30 Published Print: 2017-09-30 VIEW PDF: INVESTIGATION ON IMAGE PROCESSING PARAMETERS… Based on advantages of available modern image processing techniques, thin-layer chromatography combined with image analysis becomes a promising alternative for the mycotoxins determinations in various foodstuffs. For this, the effect of digitizing channel selection and image processing parameters on aflatoxin B2 (AB2) and ochratoxin A (OTA) determination was evaluated and the obtained results were compared with those of classical photodensitometric analysis. The best exciting wavelength for OTA was found to be λexcitation=333nm while for AB2 λexcitation=365nm. Low detection and quantification limits were determined (LODOTA=0.310ng/spot; LOQOTA=0.616ng/spot, LODAB2=0.557ng/spot, LOQAB2=1.098ng/spot). For image processing, the parameter with the highest influence upon the regression calibration curve was brightness and the best digitizing channel was found to be the green one. First-order calibration curve with a good determination coefficient (R2>0.99) were obtained on the working range of 2.5-50ng/spot. Although image processing techniques do not provide higher LOD and LOQ values than classical photodensitometry, this method offers the advantage of simultaneous quantification of both mycotoxins. Keywords: aflatoxin B1, ochratoxin A, TLC; densitometry, image processing
|
|||||||