![]()
AMBIENTUM BIOETHICA BIOLOGIA CHEMIA DIGITALIA DRAMATICA EDUCATIO ARTIS GYMNAST. ENGINEERING EPHEMERIDES EUROPAEA GEOGRAPHIA GEOLOGIA HISTORIA HISTORIA ARTIUM INFORMATICA IURISPRUDENTIA MATHEMATICA MUSICA NEGOTIA OECONOMICA PHILOLOGIA PHILOSOPHIA PHYSICA POLITICA PSYCHOLOGIA-PAEDAGOGIA SOCIOLOGIA THEOLOGIA CATHOLICA THEOLOGIA CATHOLICA LATIN THEOLOGIA GR.-CATH. VARAD THEOLOGIA ORTHODOXA THEOLOGIA REF. TRANSYLVAN
|
|||||||
Rezumat articol ediţie STUDIA UNIVERSITATIS BABEŞ-BOLYAI În partea de jos este prezentat rezumatul articolului selectat. Pentru revenire la cuprinsul ediţiei din care face parte acest articol, se accesează linkul din titlu. Pentru vizualizarea tuturor articolelor din arhivă la care este autor/coautor unul din autorii de mai jos, se accesează linkul din numele autorului. |
|||||||
STUDIA CHEMIA - Ediţia nr.1 din 2019 | |||||||
Articol: |
DETERMINATION OF NITRATE AND NITRITE CONTENT IN ZONAR MILK SERUM AND DERIVED DAIRY DRINKS USING ION-PAIR REVERSED-PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY. Autori: MIUȚA FILIP, DOINA PRODAN, MARIOARA MOLDOVAN, MIHAELA VLASSA. |
||||||
Rezumat: DOI: 10.24193/subbchem.2019.1.16 pp. 197-206 Published Online: 2019-03-30 Published Print: 2019-03-30 VIEW PDF: chem.ubbcluj.ro/~studiachemia/chemia2019_1.html The presence of nitrite and nitrate in milk and dairy products may cause serious health problem for consumers. Thus, a simple and accurate ion-pair reversed-phase high performance liquid chromatographic (IP-RP-HPLC) method has been developed and validated for determination of nitrite and nitrate in some dairy drinks based on Zonar Milk Serum. The separation was achieved on a Synergy Hydro-RP polar endcapped C18, 80Å, 4m (250 x 4.6 mm) column using isocratic elution with 0.01M n-octylamine and methanol, 90:10 (v/v) at pH=7; with flow rate of 1 mL·min-1 and detection at 214 nm and 25°C. A linear response (R2 ≥ 0.9994) was observed in the range between 3.125 and 75 µg mL-1 for the nitrite and nitrate standard solutions. The limits of detection (LOD) and quantification (LOQ) were found as 0.25 µg mL-1 and 0.8 µg mL-1 for nitrite and 0.4 µg mL-1 and 1.2 µg mL-1 for nitrate, respectively. The method was validated according to ICH guidelines with respect to selectivity, linearity, detection and quantitation limits, accuracy, precision. The good analytical performance verified for this method indicates that it is suitable the monitoring of nitrite and nitrate in dairy drinks based on Zonar Milk Serum. Keywords: Nitrite, Nitrate, IP-RP-HPLC, validation, Zonar Milk Serum dairy drinks |
|||||||
![]() |
|||||||
![]() |